<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" 
	xmlns:georss="http://www.georss.org/georss"
	xmlns:geo="http://www.w3.org/2003/01/geo/wgs84_pos#"
	>

<channel>
	<title>Sliplab</title>
	<atom:link href="https://sliplab.com.au/feed/" rel="self" type="application/rss+xml" />
	<link>https://sliplab.com.au</link>
	<description>Floor Material Slip Resistance Testing</description>
	<lastBuildDate>Thu, 13 Jan 2022 00:30:20 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/05/cropped-Logo-simple.png?fit=32%2C32&#038;ssl=1</url>
	<title>Sliplab</title>
	<link>https://sliplab.com.au</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">201690370</site>	<item>
		<title>External pavements and ramps</title>
		<link>https://sliplab.com.au/external-pavements-and-ramps/</link>
		
		<dc:creator><![CDATA[SlipLab]]></dc:creator>
		<pubDate>Mon, 22 Nov 2021 01:29:58 +0000</pubDate>
				<category><![CDATA[National Construction Code]]></category>
		<guid isPermaLink="false">https://sliplab.com.au/?p=2700</guid>

					<description><![CDATA[Australian Standard Reference SA HB:198 2014 Table 3B External ramps including sloping driveways, footpaths, etc., under 1:14, external sales areas (e.g., markets), external carpark areas, external colonnades, walkways, pedestrian crossings, verandas, carport. driveways, courtyards, and roof decks. Minimum wet pendulum classification deemed suitable P4]]></description>
										<content:encoded><![CDATA[
<p>Australian Standard Reference SA HB:198 2014 Table 3B</p>



<p>External ramps including sloping driveways, footpaths, etc., under 1:14, external sales areas (e.g., markets), external carpark areas, external colonnades, walkways, pedestrian crossings, verandas, carport. driveways, courtyards, and roof decks. Minimum wet pendulum classification deemed suitable P4</p>



<figure class="wp-block-image size-large is-style-default"><img data-recalc-dims="1" fetchpriority="high" decoding="async" width="768" height="1024" src="https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210720_140204.jpg?resize=768%2C1024&#038;ssl=1" alt="Wet pendulum testing - external pavement pavers" class="wp-image-2702" srcset="https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210720_140204.jpg?resize=768%2C1024&amp;ssl=1 768w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210720_140204.jpg?resize=225%2C300&amp;ssl=1 225w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210720_140204.jpg?resize=1152%2C1536&amp;ssl=1 1152w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210720_140204.jpg?resize=1536%2C2048&amp;ssl=1 1536w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210720_140204.jpg?resize=400%2C533&amp;ssl=1 400w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210720_140204.jpg?w=1560&amp;ssl=1 1560w" sizes="(max-width: 768px) 100vw, 768px" /><figcaption> Wet pendulum testing external pavement pavers </figcaption></figure>



<p></p>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2700</post-id>	</item>
		<item>
		<title>Stair Treads and Stairway Landings</title>
		<link>https://sliplab.com.au/stair-treads-and-stairway-landings/</link>
		
		<dc:creator><![CDATA[SlipLab]]></dc:creator>
		<pubDate>Mon, 22 Nov 2021 01:08:38 +0000</pubDate>
				<category><![CDATA[National Construction Code]]></category>
		<guid isPermaLink="false">https://sliplab.com.au/?p=2697</guid>

					<description><![CDATA[SA HB 198:2014 Table 3A applications and values have been determined by the Australian Building Codes Board for use in regulations based on the NCC Stair treads and a stairway landing (when dry &#8211; internal) Minimum wet pendulum classification deemed suitable P3]]></description>
										<content:encoded><![CDATA[
<p><strong>SA HB 198:2014</strong> Table 3A applications and values have been determined by the Australian Building Codes Board for use in regulations based on the NCC</p>



<p>Stair treads and a stairway landing (when dry &#8211; internal)  </p>



<p><strong>Minimum wet pendulum classification deemed suitable P3</strong> </p>



<p></p>



<p> </p>



<figure class="wp-block-image size-large"><img data-recalc-dims="1" decoding="async" width="768" height="1024" src="https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210928_134324.jpg?resize=768%2C1024&#038;ssl=1" alt="Wet pendulum testing on stairway landings" class="wp-image-2698" srcset="https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210928_134324.jpg?resize=768%2C1024&amp;ssl=1 768w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210928_134324.jpg?resize=225%2C300&amp;ssl=1 225w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210928_134324.jpg?resize=1152%2C1536&amp;ssl=1 1152w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210928_134324.jpg?resize=1536%2C2048&amp;ssl=1 1536w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210928_134324.jpg?resize=400%2C533&amp;ssl=1 400w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/11/20210928_134324.jpg?w=1560&amp;ssl=1 1560w" sizes="(max-width: 768px) 100vw, 768px" /></figure>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">2697</post-id>	</item>
		<item>
		<title>NATA Accreditation</title>
		<link>https://sliplab.com.au/nata-accreditation/</link>
		
		<dc:creator><![CDATA[Slip Lab]]></dc:creator>
		<pubDate>Thu, 09 Sep 2021 04:03:42 +0000</pubDate>
				<category><![CDATA[Slip Lab Sydney]]></category>
		<category><![CDATA[Slip resistance testing]]></category>
		<guid isPermaLink="false">https://sliplab.com.au/?p=2682</guid>

					<description><![CDATA[Slip Lab has NATA Accreditation, (Accreditation No 20858) which means you can be assured that our standards meet the highest guidelines. When&#160;businesses&#160;choose&#160;a NATA accredited&#160;supplier&#160;they can be sure that:&#160; Accredited specifications will be met  There will be certainty and reliability in the supply chain They can rely on the supplier’s technical competence and capability  Like can be compared to [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p>Slip Lab has NATA Accreditation, (Accreditation No 20858) which means you can be assured that our standards meet the highest guidelines.</p>



<p>When&nbsp;businesses&nbsp;choose&nbsp;a NATA accredited&nbsp;supplier&nbsp;they can be sure that:&nbsp;</p>



<div class="wp-block-image"><figure class="alignright size-medium"><img data-recalc-dims="1" decoding="async" width="210" height="300" src="https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/05/725038.NATA_WRA_NEG1_RGB.jpg?resize=210%2C300&#038;ssl=1" alt="NATA - World recognised accreditation" class="wp-image-2473" srcset="https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/05/725038.NATA_WRA_NEG1_RGB.jpg?resize=210%2C300&amp;ssl=1 210w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/05/725038.NATA_WRA_NEG1_RGB.jpg?resize=717%2C1024&amp;ssl=1 717w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/05/725038.NATA_WRA_NEG1_RGB.jpg?resize=768%2C1097&amp;ssl=1 768w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/05/725038.NATA_WRA_NEG1_RGB.jpg?resize=140%2C200&amp;ssl=1 140w, https://i0.wp.com/sliplab.com.au/wp-content/uploads/2021/05/725038.NATA_WRA_NEG1_RGB.jpg?w=783&amp;ssl=1 783w" sizes="(max-width: 210px) 100vw, 210px" /></figure></div>



<ul class="wp-block-list"><li>Accredited specifications will be met </li><li>There will be certainty and reliability in the supply chain</li><li>They can rely on the supplier’s technical competence and capability </li><li>Like can be compared to like in a competitive market-place </li><li>They are show-casing a quality-centric approach </li><li>They will reduce the risk of failure and downtime </li><li>Measurements and tests are accurate and have been carried out in compliance with best practice. </li></ul>



<p>NATA is Australia’s leading national accreditation body, recognised by government to assess organisations against a number of international standards for laboratories, inspection bodies, proficiency testing scheme providers and reference material producers. NATA provides accreditation services to conformity assessment bodies which facilitate stakeholders having confidence in test, measurement and inspection data and thus enabling them to gain national and international acceptance of their products and services. </p>



<p><a href="https://nata.com.au/" target="_blank" rel="noreferrer noopener">For more information visit NATA here</a>.</p>